Drive System

Water Cooling Motor

Generally, smaller motors use air cooling to reduce the surface temperature of the motor housing to achieve heat dissipation. However, for high-torque drive motors such as 10-12m electric buses/tourist buses, if the air-cooling method is still used, the heat dissipation effect of the motor will be relatively poor. The operating temperature of the motor is usually 90°C, which affects the motor efficiency And reduce the life of the motor. The water-cooled drive motor designed by our company does not have a heat sink on the outer surface of the casing, which reduces the size and weight of the motor and facilitates the layout of the car chassis. And because of the reduction in weight, battery energy can be saved, and the driving range of electric vehicles can be extended. Motor features: high-torque regenerative braking has high recovery efficiency, low water-cooled heat dissipation temperature rise, shock resistance, high reliability, and long service life.

Type

DRIVE250KW3600N

Rated Current

195 A

Rated Power

110 kW

Rated frequency

36 Hz

Rated Torque

1000 N·m

Rated power factor

0.93

Rated Speed

1000 r/min

Weight

526kg

Peak Power

270 kW

IP Class

IP67

Peak Torque

3600 N·m

Insulation

F(<155℃)

Peak Speed

3000 r/min

Mode Duty

S1Continuous work

Rated Voltage

380 V